INSTRUCTION MANUAL
BLACKHAWK SERIES
BROADBAND POWER SUPPLIES
Installation and Operation Manual
Manual Part No:
017-027-B0
Issue 01 (01/23/06)
1
Page view 0
1 2 3 4 5 6 ... 30 31

Summary of Contents

Page 1 - INSTRUCTION MANUAL

INSTRUCTION MANUAL BLACKHAWK SERIES BROADBAND POWER SUPPLIES Installation and Operation Manual Manual Part No:017-027-B0 Issue 01 (01

Page 2

As shown in Fig. 2-1, output voltage never decreases below 90% of full output rating during the source transfer. Output voltage recovers to full rate

Page 3 - 1350 VA OUTPUT RATING

Missing or Damaged Items If items are found to be damaged or missing, contact the shipping company and your Multilink Broadband representative immedi

Page 4

conductors shall be connected to the power supply through an appropriate service entrance equipment. Permission to mount the UPS on the utility pole

Page 5

General Installation Procedure: Ground Mounted Cabinet The following procedure is intended as a general guideline only for ground-mounting a cabinet

Page 6

5. INSTALLATION NOTE: Do not install batteries until verifying that the cabinet mounting hardware is secure. Failure to do so may result in the cabin

Page 7

CABINET INDICATORS: Mini Mate-N-Lok: connects the enclosure alarm and status lamps to the power supply for external status indication. The power sup

Page 8

Section 5: Installation and Setup Installing and wiring any model within the Blackhawk Series power supplies into an enclosure may be accomplished

Page 9 - Section 2: lntroduction

The power supply should be mounted on a ventilated shelf that allows free air circulation, especially through the front and rear panels on the right s

Page 10

4) Connect the AC line cord from the power supply to the appropriate AC receptacle. 5) Insert the battery plug from the battery wiring harness into

Page 11

Battery Installation Procedure: 1. Place the batteries on the lower shelf of the enclosure, positive terminal facing out. 2. Route the terminal co

Page 12

Documented Power Supply Models The following power supply models, with their part numbers, are documented by this instruction manual. For available

Page 13

Section 6: Startup and Operation The power supply is ready to be placed into operation after it has been installed in its enclosure and all input

Page 14

Front Panel Status Indicators: Verify the status of the power supply from the LED display during normal operation. All indicator LEDs are located on

Page 15

1. Operate the toggle of the BATTERY CIRCUIT breaker to the OFF position, then disconnect the battery cable from the power supply. 2. Disconnect t

Page 16

Battery Balance Manager: This accessory, available as a separate assembly, is designed to maintain identical terminal voltage of each 6-cell battery

Page 17

YELLOWBLUETB1 TB2ORANGEWH / BKBK / WHWHITEBLACK90V75V60VOUTPUT VOLTAGESELECT WIRETRANSFORMERINPUT POWERWIRE (WHITE)INPUT POWERWIRE (BL

Page 18

DANGER Performing the following procedure exposes the servicing technician to hazardous voltages and will disrupt power to the system loads. The ser

Page 19

DANGER Performing the following procedure exposes the servicing technician to hazardous voltages and will disrupt power to the system loads. The ser

Page 20

INDICATES JUMPERCONNECTED OVERDESIGNATED PINS864231 5784261240V SETTING735700-064-21OUTPUT INTERFACEPCB ASSEMBLY700-064-20J1T1J10RELAY K2INSTALLED HER

Page 21

performance reporting, the entire inverter module should be changed in the field. The module with suspected problems should be returned to a service

Page 22 - Section 8: Options

Section 10: Specifications Black Hawk 600-120/60-36 or 600-120/60-48 AC Input Voltage ……………………… 120 volts AC, nominal Nominal Input Voltage

Page 23

1350 VA OUTPUT RATING MODEL NUMBER PART NUMBER INPUTS 1350-120/60-36 017-030-20 120VAC, 60Hz, 3-Battery

Page 24 - 90V75V60V

Specifications (cont’d) Black Hawk 900-120/60-36; 900-120/60-48; 900-240/60-36; 900-240/60-48 AC Input Voltage ……………………… 120 volts or 240 volts A

Page 25

Specifications (cont’d) Black Hawk 1350-120/60-36; 1350-120/60-48; 1350-240/60-36; 1350-240/60-48 AC Input Voltage ……………………… 120 volts or 240 vol

Page 26

Table of Contents Blackhawk Series Broadband Power Supply Section 1: Critical Safety Issues………………………………………….….5 Safety Admonishments Emergency

Page 27

Section 9: Maintenance and Adjustments ...…….….……23 Preventive Maintenance Output Voltage Reconfiguration Input Voltage Configura

Page 28

Emergency Shutdown Procedure DANGER Exercise extreme caution when performing the following procedure. Carry out the steps precisely in the order g

Page 29

Safety Issues of Power Supply Installation and Use The subject power supply has been designed and built to power CATV and broadband distribution equi

Page 30 - Specifications (cont’d)

cannot be attained, a suitable forced-air cooling system may be required within the cabinet. Battery Safety Issues When installing batteries for the

Page 31

Section 2: lntroduction Blackhawk Series Product Overview The MultiPower Blackhawk Series power supplies provide filtered and regulated AC output